| All functions of the air conditioning system do not operate
|
IG power source circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower operation
|
Blower motor circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower control
|
Blower motor circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: Insufficient air flow
|
Blower motor circuit
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: Cooling effectiveness is poor
|
Refrigerant shortage check using the GTS
|
|
| Refrigerant volume
|
-
|
| Refrigerant pressure
|
|
| Cooler expansion valve
|
|
| Compressor assembly with pulley*1
|
|
| Compressor assembly with pulley*2, 3
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: No cool air comes out
|
Refrigerant shortage check using the GTS
|
|
| Refrigerant volume
|
-
|
| Refrigerant pressure
|
|
| Air mix damper control cable sub-assembly
|
|
| Heater control switch circuit
|
|
| Air conditioner pressure sensor circuit
|
|
| Compressor solenoid circuit
|
|
| Evaporator temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| Cooler expansion valve
|
|
| Air conditioning amplifier assembly
|
|
| ECM*1
|
|
| ECM*2
|
|
| ECM*3
|
|
| Temperature control: No warm air comes out
|
Air mix damper control cable sub-assembly
|
|
| Heater control switch circuit
|
|
| Ambient temperature sensor circuit
|
|
| Air conditioning amplifier assembly
|
|
| ECM*1
|
|
| ECM*2
|
|
| ECM*3
|
|
| Temperature control: Output air is warmer or cooler than the set temperature or response is slow
|
Refrigerant shortage check using the GTS
|
|
| Refrigerant volume
|
-
|
| Refrigerant pressure
|
|
| Air mix damper control cable sub-assembly
|
|
| Compressor solenoid circuit
|
|
| Ambient temperature sensor circuit
|
|
| Heater radiator unit sub-assembly
|
|
| Cooler expansion valve
|
|
| Air conditioning amplifier assembly
|
|
| ECM*1
|
|
| ECM*2
|
|
| ECM*3
|
|
| Temperature control: No temperature control (only MAX COLD or MAX HOT)
|
Heater control switch circuit
|
|
| Air mix damper control cable sub-assembly
|
|
| Ambient temperature sensor circuit
|
|
| Evaporator temperature sensor circuit
|
|
| Air conditioning amplifier assembly
|
|
| No air inlet control
|
No. 1 blower damper servo motor circuit
|
|
| Air conditioning amplifier assembly
|
|
| No air flow mode control
|
No. 1 heater control sub-assembly
|
|
| No. 2 heater control sub-assembly
|
|
| Diagnostic Trouble Codes (DTCs) are not recorded. Set mode is cleared when the ignition switch is turned off
|
Air conditioning amplifier assembly
|
|