2NZ-FE ENGINE CONTROL  ECM  INSTALLATION  


PROCEDURE

Hide 89668 1.INSTALL NO. 2 ECM BRACKET

a.

Install the No. 2 ECM bracket to the ECM with the 2 screws.

Torque:
3.0 N*m (31 kgf*cm, 27 in.*lbf)


Hide 89667 2.INSTALL NO. 1 ECM BRACKET

a.

Install the No. 1 ECM bracket to the ECM with the 2 screws.

Torque:
3.0 N*m (31 kgf*cm, 27 in.*lbf)


Hide 89661 3.INSTALL ECM

a.

Engage the clamp and install the ECM with the 3 bolts.

Torque:
12.5 N*m (127 kgf*cm, 9 ft.*lbf)

NOTICE:

If the ECM has been struck or dropped, replace it.



b.
A316187

Engage the wire harness clamp.


c.

Connect the 2 ECM connectors and lower the 2 levers.

NOTICE:
·

When connecting the ECM connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the ECM connectors.

·

Be sure to securely connect the ECM connectors.




Hide 17751 4.INSTALL INLET NO. 1 AIR CLEANER

a.

Install the inlet No. 1 air cleaner with the bolt.

Torque:
7.0 N*m (71 kgf*cm, 62 in.*lbf)


Hide 17701 5.INSTALL AIR CLEANER CASE SUB-ASSEMBLY

Hide 17705 6.INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE

Hide 11212 7.INSTALL NO. 2 CYLINDER HEAD COVER

Hide 8.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 9.PERFORM INITIALIZATION