2ZR-FE STARTING STARTER INSTALLATION
PROCEDURE
28100
1.INSTALL STARTER ASSEMBLY
a.
Install the starter assembly with the 2 bolts.
- Torque:
- 37 N*m (377 kgf*cm, 27 ft.*lbf)
b.
Connect the starter assembly connector.
c.
Connect terminal 30 with the nut.
- Torque:
- 9.8 N*m (100 kgf*cm, 87 in.*lbf)
d.
Close the terminal cap.
51441C
2.INSTALL ENGINE UNDER COVER RH
3.INSTALL ENGINE UNDER COVER LH
4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
- NOTICE:
-
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
-
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION