HEATING / AIR CONDITIONING AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) B1451/51 Compressor Solenoid Circuit
DESCRIPTION
In this circuit, the compressor assembly with pulley (compressor solenoid) receives a refrigerant compression demand signal from the air conditioning amplifier assembly.
Based on this signal, the compressor assembly with pulley (compressor solenoid) changes the amount of compressor output.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1451/51 | Compressor Solenoid Circuit | Open or short in compressor solenoid circuit | ·
Compressor assembly with pulley (compressor solenoid) ·
Harness or connector between air conditioning amplifier assembly and compressor assembly with pulley (compressor solenoid) ·
Air conditioning amplifier assembly |
- |
WIRING DIAGRAM
PROCEDURE
Disconnect the B8 compressor assembly with pulley (compressor solenoid) connector.
| *a | Component without harness connected
(Compressor Assembly with Pulley (Compressor Solenoid)) |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 (SOL-) - 2 (SOL+) 20°C (68°F) 10.1 to 11.1 Ω
- Result:
Proceed to OK NG
OK
NG
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition B8-1 (SOL-) - Body ground Always Below 1 Ω
- Result:
Proceed to OK NG
OK
NG
Disconnect the E102 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition E102-2 (SOL+) - B8-2 (SOL+) Always Below 1 Ω E102-2 (SOL+) or B8-2 (SOL+) - Body ground Always 10 kΩ or higher
- Result:
Result Proceed to NG A OK (When troubleshooting according to the Problem Symptoms Table) B OK (When troubleshooting according to the DTC) C
A
B
C