SPECIFICATIONS 2ZR-FE COOLING SERVICE DATA
Condition | Specified Condition |
---|---|
Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
Standard valve lift | 8.5 mm (0.335 in.) or more at 95°C (203°F) |
Condition | Specified Condition |
---|---|
Battery voltage applied at 20°C (68°F) | 7.4 to 10.9 A |
Tester Connection | Condition | Specified Condition |
---|---|---|
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
3 - 5 | Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Item | Condition | Specified Condition |
---|---|---|
Radiator cap | Standard value (for brand-new cap) | 74 to 103 kPa (0.8 to 1.1 kgf/cm2, 10.7 to 14.9 psi) |
Minimum standard value (for used cap) | 59 kPa (0.6 kgf/cm2, 8.6 psi) |
Capacity | Classification |
---|---|
5.2 liters (5.5 US qts, 4.6 Imp. qts) | Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids). |