2NZ-FE EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 25860 1.INSPECT PURGE VALVE (PURGE VSV)

a.
A194073
0.104,0.042 0.417,0.198 0.313,0.156 10 false *a
*a Component without harness connected
(Purge Valve (Purge VSV))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω


If the result is not as specified, replace the purge valve (purge VSV).


b.
A282778
0.542,0.438 0.448,0.438 0.448,0.438 0.448,1.104 false 0.938,1.813 1.042,1.813 1.042,1.813 1.104,1.323 false 0.74,1.74 1.052,1.896 0.313,0.156 10 false *a 0.583,0.365 0.896,0.521 0.313,0.156 10 false *b 1.583,1.708 1.896,1.865 0.313,0.156 10 false *c 2.115,0.156 2.427,0.354 0.313,0.198 10 false *d
*a Port (E)
*b Port (F)
*c Air
*d Component without harness connected
(Purge Valve (Purge VSV))


Apply battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).

Standard:
Condition Specified Condition
Battery voltage applied between terminals 1 and 2 Air flows from port (F)
Battery voltage not applied between terminals 1 and 2 Air does not flow


If the result is not as specified, replace the purge valve (purge VSV).